MiniUnix/usr/man/man4/dn.4
.th DN IV 3/20/74
.sh NAME
dn \*- DN-11 ACU interface
.sh DESCRIPTION
The
.it dn?
files
are write-only.
The permissible codes are:
.s3
.lp +8 4
0-9 dial 0-9
.lp +8 4
: dial *
.lp +8 4
; dial #
.lp +8 4
\*- 4 second delay for second dial tone
.lp +8 4
= end-of-number
.s3
.i0
The entire telephone number must be
presented in a single
.it write
system call.
.s3
It is recommended that an end-of-number
code be given even though not all
ACU's actually require it.
.dt
.sh FILES
/dev/dn0 connected to 801 with dp0
.br
/dev/dn1 not currently connected
.br
/dev/dn2 not currently connected
.sh "SEE ALSO"
dp (IV)
.sh BUGS